G1000
Input voltage: 220V 0.7kW-2.2kW
380v 0.7kW-2.2kW
Control Mode: Space vector, V/F control
Start Torque: 0.0~20.0%
Input |
Nominal voltage & frequency |
Single-phase, three-phase AC220V,AC380V 50/60Hz |
Allowable voltage range |
Single-phase, three-phase AC170~240V;AC340~440V |
|
Nominal voltage & frequency |
Single-phase, three-phase AC220V,AC380V 50/60Hz |
|
Output |
Voltage |
220V:0~220V;380V:0~380V |
Frequency |
0.1~400.0Hz |
|
Control mode |
Space vector, V/F control |
|
Display |
Quadbit nixie tube display & indicator display: set frequency, output frequency, output current, rotating direction, rotating speed and fault, etc. |
|
Working conditions |
Environmental temperature: -10℃~40℃ (non-freezing) Relative humidity: 90% below (non-condensing) Altitude: 1000m below Vibration: 0.5G below |
|
Structure |
Cooling mode: forced air cooling Protection grade: IP20 |
|
Installation |
Wall-mounted |
Control characteristics |
Frequency setting resolution |
Digital setting: 0.1Hz, simulated setting: 0.1% of the maximum output frequency |
Output frequency accuracy |
0.1Hz |
|
V/F control |
V/F curve can be freely set to comply with various loads. |
|
Torque control |
Automatic boosting: the torque boosting can be fixed automatically according to the actual load; Manual boosting: 0.0~20.0% torque boosting is settable. |
|
Multifunctional input |
6 multifunctional input terminals for 15-step speed control, programmed operation, 4-step accelerating or decelerating switch, UP/DOWN and emergency stop functions, etc. |
|
Multifunctional output |
2 multifunctional output terminals for indicating and warning for operating, null speed, external irregularity and programmed operation, etc. |
|
Accelerating/ decelerating time setting |
0~999.9s separately settable accelerating/ decelerating time |
|
Other functions |
Built-in PID control and 2 counter units, standard RS485 communication function and selectable automatic voltage regulation; Frequency setting mode: analog quantity 0~10V, 0~20mA, manipulator setting, RS485 setting and up/down setting, etc |
|
Protective functions |
Overload protection: 150% constant torque for 1 minute, settable over-voltage/ under-voltage protection; Other protections: overheat protection, short circuit protection, overcurrent protection and parameter lock, etc. |